Part Number Hot Search : 
0505S P6KE91C ZL30102 74HC14M NTE3056 M3501 ULY7701N MB91302A
Product Description
Full Text Search
 

To Download PPS-200 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 200W Single Output with PFC Function
Features :
PPS-200
series
Universal AC input / Full range Built-in active PFC function High efficiency up to 90% (typ) Protections: Short circuit / Overload / Over voltage / Over temperature PWM control and regulated High power density 9.78W/inch3 5"x3" compact size Built-in remote sense function ZVS technology to reduce power dissipation Free air convection for 150W and 200W with 20.5 CFM forced air 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT PPS-200-5 5V 36A PPS-200-12 12V 16.6A 0 ~ 12.5A 0 ~ 16.6A 150W 199.2W 100mVp-p 10.8 ~ 13.2V 3.0% 0.5% 1.0% PPS-200-15 15V 13.3A 0 ~ 10A 0 ~ 13.3A 150W 199.5W 100mVp-p 13.5 ~ 16.5V 3.0% 0.5% 1.0% 2500ms, 60ms/115VAC at full load PPS-200-24 24V 8.3A 0 ~ 6.25A 0 ~ 8.3A 150W 199.2W 150mVp-p 21.6 ~ 26.4V 2.0% 0.5% 1.0% PPS-200-27 27V 7.4A 0 ~ 5.56A 0 ~ 7.4A 150W 199.8W 150mVp-p 24.3 ~ 30V 2.0% 0.5% 1.0% PPS-200-48 48V 4.167A 0 ~ 3.13A 0 ~ 4.167A 150W 200W 250mVp-p 43.2 ~ 52.8V 2.0% 0.5% 1.0%
CURRENT RANGE (convection) 0 ~ 26A CURRENT RANGE (20.5CFM FAN) 0 ~ 36A RATED POWER (convection) 130W RATED POWER (20.5CFM FAN) 180W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 4.0% 0.5% 1.0%
1200ms, 60ms/230VAC 90 ~ 264VAC 47 ~ 63Hz PF>0.93/230VAC 86%
12ms/230VAC/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 89% 89% 89% 89% 90%
2.2A/115VAC 1.2A/230VAC COLD START 70A/230VAC <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.6 ~ 7.25V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF 108.4Khrs min. MIL-HDBK-217F (25 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT )
ISOLATION RESISTANCE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 can not be shorted. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:PPS-200-SPEC 2008-10-22
200W Single Output with PFC Function
Mechanical Specification
127 5 115.6 12
6.4
PPS-200
series
Unit:mm
HS2 CN3 HS1 SVR1 1 2 3 4 5 6 7 8 CN5 LED1
76.2
64.8
1 2 3 CN1
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3
43. 5
Assignment AC/L No Pin AC/N
Mating Housing JST VHR or equivalent
Terminal JST SVH-21T-P1.1 or equivalent
50mm
Air flow direction 20.5CFM
DC Output Connector (CN5) : JST B8P-VH or equivalent
Pin No. 1~4 5~8 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
FAN
Remote Sense(CN3) : Molex 5045-02 or equivalent
Pin No. 1 2 Assignment RSRS+
34.6
Mating Housing Molex 5051 or equivalent
Terminal Molex 4809 or equivalent
3max.
HS1,HS2 can not be shorted
Block Diagram
EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER
fosc : 100KHz
I/P
+V -V
FG
DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta = 25
125 100
100
With FAN
90 80
70
70
LOAD (%)
50
Without FAN
LOAD(%)
60 70 (HORIZONTAL)
60 50 40
20
-20
0
10
20
30
40
50
90
115
125
135
155
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:PPS-200-SPEC 2008-10-22


▲Up To Search▲   

 
Price & Availability of PPS-200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X